Specialty Fluorescent pigment

NAP|2A

NAP-2A is a universal type of sensor for flammable gases and can be used for gas detectors as well as for gas densitometers. The following are the ratings and output characteristics of this sensor. It is recommended to refer to the individual userfs manual for further information.


Target gases and concentration

Gases Detection range
Methane CH4 0.05 ~ 5“(0.05 ~ 2“)
Propane C3H8 0.03 ~ 2.2“(0.03~ 1“)
Iso-butane Iso-C4H10 0.03 ~ 1.8“(0.03 ~ 0.8“)
Hydrogen H2 0.05 ~ 4“(0.05 ~ 1.5“)
Ethanol C2H5OH 0.05 ~ 3.2“(0.05 ~ 1.5“)
Hydrocarbons CnH2n+2 1~100% LEL (1~50%LEL)

(@)is a detection range in high accuracy


Ratings

Items Specifications
Supply voltage DC 2.20 +/- 0.22‚u
AC 2.20 +/- 0.22‚u (r.m.s. 50~60Hz)
Current(When 2.2V is supplied) DC 340 ~ 380mA
AC 340 ~ 380mA (r.m.s. 50~60Hz)
Ambient Temperature In operation -10 ~ +50Ž
In storage -10 ~ +60Ž
Ambient humidity In operation 95“RH or less
In storage 99“RH or less(No dew condensation)

Gas sensitivity characteristics

Gas & Concentration Output voltage
Output in clean air -35 ~ +35 mV
Methane 3000ppm 14 ~ 22 mV
Iso-butane 1400ppm 12 ~ 18 mV
Hydrogen 1400ppm 9 ~ 15 mV
Ethanol 1400ppm Less than 15mV

Recommended measuring circuit Gas sensitivity characteristics