NAP−503
NAP-503 is a newly-developed version of NAP-505. The appearance and structure are exactly same as NAP-505, but this new version has a lower sensitivity to hydrogen gas. While NAP-505’s sensitivity to hydrogen gas is about 40% of the sensitivity to CO gas, but NAP-503’s sensitivity to hydrogen gas is only about 10% of the sensitivity to CO gas. Thus NAP-503 has much better gas selectivity. An appropriate type can be selected depending on users’ applications. As there are various types of NAP-503 as shown below, please contact us for detailed information.
Characteristics
| Detection range |
CO 0 ~ 1,000ppm |
Zero point drift |
<10ppm (-20 ~ 50oC) |
| Output current |
40±10nA/ppmCO |
Temp. & humidity |
-20 ~ 50oC, 15 ~ 90%RH |
| Repeatability |
Less than ± 2% |
Span drift |
Less than 5%/Year |
| Response time |
T90: Within 30 sec. |
Life |
More than 5 years |