Various sensor products

NAP|55A

NAP-55A is a miniature & low power consumption type of NAP-2A, and is mainly used for gas detectors and leak testers. 55A is a half in height and needs a half in power consumption compared to 2A so that thinner and lighter-weight detectors can be produced. The following are the basic characteristics but it is recommended to refer to the individual userfs manual for further information. A measuring circuit for sensor evaluation is the same as NAP-2A.


Target gases and concentration

Gases Detection range
Methane CH4 0.05|5“(0.05|2“)
Propane C3H8 0.03|2.2“(0.03|1“)
Iso-butane Iso-C4H10 0.03|1.8“(0.03|0.8“)
Hydrogen H2 0.05|4“(0.05|1.5“)
Ethanol C2H5OH 0.05|3.2“(0.05|1.5“)
Hydrocarbons CnH2n+2 1-100%LEL(1-50%LEL)

( ) is a detection range in high accuracy


Ratings

Items Specifications
Supply Voltage DC 2.5 +/- 0.25V
AC 2.5+/- 0.25V (r.m.s. 50~60Hz)
Current
(When 2.5V is applied)
DC 150 ~ 170mA
AC 150 ~ 170mA (r.m.s. 50~60Hz)
AmbientTemperature In operation -10 ~ +50Ž
In storage -10 -~+50Ž
Ambient humidity In operation 95“RH or less
In storage 99“RH or less
(No dew condensation)

Gas sensitivity characteristics

Gases & concentration Output voltage
Output in clean air -35 ~ +35mV
Methane 3000ppm 10 ~ 16mV
Iso-butane 1400ppm 10 ~ 15mV
Hydrogen 1400ppm 7 ~ 12mV
Ethanol 1400ppm Less than 11mV

Gas sensitivity characteristics Response characteristics