Various sensor products
NAP|56A
NAP-55A has been followed by a new version, NAP-56A that is not made with thermoplastics to achieve a higher temperature resistivity. The pin locations and dimensions are compatible to NAP-55A for the convenience of current users of Nemoto NAP-55A. The gas sensitivity is better than NAP-55A by about 15%. Users are to pay attention to this higher gas sensitivity upon calibration.
Fig. Appearance and structure of NAP|56A |
 |
Target gases & concentration
| gases |
Detection range |
| Methane |
CH4 |
0.05|5%(0.05|2%) |
| Ethane |
C2H6 |
0.05|3.2“(0.05|1.5“) |
| Hydrogen |
H2 |
0.05|4“(0.05|1.5“) |
| Hydro-carbons |
CnH2n+2 |
1-100%LEL(1-50%LEL) |
(@) = Detection range with high accuracy
Ratings
| Item |
Ratings |
| Supply voltage |
DC 2.5}0.25V
AC 2.5}0.25V(RMS 50-60Hz)
|
| Current(2.5Vapplied) |
DC 150|170mA
AC 150|170mA(RMS 50-60Hz)
|
| Ambient temperature |
Usage |10 ~ +50Ž
Storage |10 ~ +50Ž
|
| Ambient humidity |
Usage 95“RH or less
Storage 99“RH or less but no dewCondensation.
|
Gas sensitivity characteristics
| Gases and concentration |
Output values |
| Output in clean air |
|35 ~ +35mV |
| Methane 3,000ppm |
15 ~ 23mV |
| Iso-butane 1,400ppm |
12 ~ 18mV |
| Hydrogen 1,400ppm |
10 ~ 17mV |