Various sensor products

NAP|66A

NAP-66A is a miniature & low power consumption type of NAP-3A, and is mainly used for gas detectors and leak testers. 66A is a half in height and needs a half in power consumption compared to 3A so that thinner and lighter-weight detectors can be produced. The following are the basic characteristics but it is recommended to refer to the individual userfs manual for further information. A measuring circuit for sensor evaluation is the same as NAP-3A.


Target gases and concentration

Gases Detection range
Propane C3H8 0.03 ~ 2.2% (0.03 ~ 1%)
Iso-butane Iso-C4H10 0.03 ~ 1.8% (0.03 ~ 0.8%)
Hydrogen H2 0.05 ~ 4% (0.05 ~ 1.5%)
Ethanol C2H5OH 0.05 ~ 3.2% (0.05 ~ 1.5%)
Hydrocarbons CnH2n+2 1~100% LEL (1~50%LEL)

( ) is a detection range in high accuracy

Ratings

Items Ratings
SupplyVoltage DC 2.0 } 0.2V
AC 2.0 } 0.2V (r.m.s. 50~60Hz)
Current(When 2.0V is applied)
DC 140 ~ 160mA
AC 140 ~ 160mA (r.m.s. 50~60Hz)
AmbientTemperature In operation -10 ~ +50Ž
In storage -10 ~ +50Ž
Ambienthumidity In operation 95%RH or less
In storage 99%RH or less(No dew condensation)

Gas sensitivity characteristics

Gases and concentration Output voltage
Output in clean air -35 ~ +35mV
Iso-butane 1400ppm 10 ~ 15mV
Hydrogen 1400ppm 7 ~ 12mV
Ethanol 1400ppm Less than 11mV

Gas sensitivity characteristics Response characteristics