Various sensor products

NAP|67A

NAP-66A has been followed by a new version, NAP-67A that is not made with thermoplastics to achieve a higher temperature resistivity. The pin locations and dimensions are compatible to NAP-66A for the convenience of current users of Nemoto NAP-66A. The gas sensitivity is better than NAP-66A by about 15%. Users are to pay attention to this higher gas sensitivity upon calibration.

Fig. Appearance and structure of NAP|67A

 


Gas sensitivity characteristics

Gases Detection range
Propane C3H8 0.03|2.2% (0.03|1%)
Iso-butane C4H10 0.03|1.8% (0.03|1%)
Hydrogen H2 0.05|4%(0.05|1.5%)
Hydrocarbons CnH2n+2 1-100%LEL(1-50%LEL)

(@) = Detection range with high accuracy

Ratings

Items Ratings
Supply voltage DC 2.0}0.2V
AC 2.0}0.2V(RMS 50-60Hz)
current (2.0V applied) DC 140|160mA
AC 140|160mA(RMS 50-60Hz)
Ambient temperature Usage |10@|@+50Ž
Storage |10@|@+50Ž
Ambient humidity Usage 95“RH or less
Storage 99“RH or less but no dew condensation

Gas sensitivity characteristics

Gases and concentration Output values
Output in clean air |35 ~ +35mV
Iso-butane 1,400ppm 12 ~ 18mV
Hydrogen 1,400ppm 10 ~ 17mV
Ethanol 1,400ppm 8 ~ 16mV