Various sensor products
NAP|67A
NAP-66A has been followed by a new version, NAP-67A that is not made with thermoplastics to achieve a higher temperature resistivity. The pin locations and dimensions are compatible to NAP-66A for the convenience of current users of Nemoto NAP-66A. The gas sensitivity is better than NAP-66A by about 15%. Users are to pay attention to this higher gas sensitivity upon calibration.
 |
 |
Fig. Appearance and structure of NAP|67A |
|
Gas sensitivity characteristics
| Gases |
Detection range |
| Propane |
C3H8 |
0.03|2.2%
(0.03|1%) |
| Iso-butane |
C4H10 |
0.03|1.8%
(0.03|1%) |
| Hydrogen |
H2 |
0.05|4%(0.05|1.5%) |
| Hydrocarbons |
CnH2n+2 |
1-100%LEL(1-50%LEL) |
(@) = Detection range with high accuracy
Ratings
| Items |
Ratings |
| Supply voltage |
DC 2.0}0.2V
AC 2.0}0.2V(RMS 50-60Hz) |
| current (2.0V applied) |
DC 140|160mA
AC 140|160mA(RMS 50-60Hz) |
| Ambient temperature |
Usage |10@|@+50Ž
Storage |10@|@+50Ž |
| Ambient humidity |
Usage 95“RH or less
Storage 99“RH or less but no dew condensation |
Gas sensitivity characteristics
| Gases and concentration |
Output values |
| Output in clean air |
|35 ~ +35mV |
| Iso-butane 1,400ppm |
12 ~ 18mV |
| Hydrogen 1,400ppm |
10 ~ 17mV |
| Ethanol 1,400ppm |
8 ~ 16mV |