NCP-180SH

NCP-180SH gas sensor is a single header type hydrogen gas sensor for industrial application, and it has been already available in many customers for fixed applications. This type has a simplified explosion proof structure, however it is recommended that it is installed in the approved body by ATEX, CSA or etc.

Dimensions

  • Diameter of base φ16.5
  • Diameter of strainer φ13
  • Height         φ15
  •  Pin length       φ6

sns_pdf_baner

NCP-180SH's Structure

Target gases and Concentration

Relative sensitivity
Gases LEL Relative
1 Methane 5.00% 0
2 Propane 2.20 0
3 n-Butane 1.80 0
4 n-Pentane 1.40 5
5 n-Hexane 1.20 10
6 n-Heptane 1.05 30
7 n-Octane 0.95 20
8 Methanol 6.70 100
9 Ethanol 3.30 40
10 IPA 2.20 45
11 Acetylene 2.50 -
12 CO 12.50 115
13 Acetone 2.60 45
14 MEK 1.90 45
15 Toluene 1.20 70
16 Ethyl acetate 2.20 10
17 Hydrogen 4.00 100
18 Ammonia 15.00 120
19 Gasoline Pb free 1.20 10
20 Ethylene 2.70 65
* : 「-」 means that it is not a detected gas.
** : R.S. (relative sensitivity) is described in case that sensitivity to hydrogen is 100.

Gas sensitivity characteristics

Gas & Concentration Output voltage
 Standard sensitivity 10%LEL of hydrogen  35 - 50mV
Zero offset in air -30 - +30mV

Ratings

Items Ratings
Supply voltage 1.6 V
Current (1.6V supplied) 130 - 150mA
Ambient Temperature In operation -20 - +60°C
Ambient humidity In operation 95%RH or less (No dew condensation)
Measurement range Less than 100%LEL